However double insulated pumps are rare so that doesn t normally come up.
Bonding a double insulated pool pump.
Grounding enables faster circuit breaker action and bonding ties conductive metal parts together so they have the same electrical potential.
If it is double insulated you don t have to bond it but you do have to provide a bond wire that can be used if a replacement motor is installed that is not double insulated.
The goal of bonding is to prevent electrical current from flowing through people who are in or touching the water.
A listed cord and plug connected pool pump incorporating an approved system of double insulation that provides a means for grounding only the internal and nonaccessible noncurrent carrying metal parts of the pump shall be connected to any wiring method recognized in chapter 38 that is suitable for the location.
Insulated ground wire is required for grounding pumps.
There s some possibility that a double insulated motor which didn t have a bonding jumper installed might be replaced by a motor that isn t double insulated resulting in a noncompliant installation.
Check to see if the pump is listed as double insulated.
In this case which i understand to be your case i would recommend installing a full driven ground rod immediately adjacent to the pool preferably in the dampest location around the pool and tying the bonding wire to that ground rod.
I took a little bonus footage from another video to make this one about pool bonding.
If the motor is double insulated it might not have a bond lug.
Together both reduce the risk of fatal shock.
But it s not practical to tie the ground system to the bond field on ag pools using a double insulated pump and serviced by a 2 wire feeder protected by a gfci.